A Damper That Opens Fully and Shuts Tight
Request Chimney Damper Repair
Note the fireplace type and, if the label is readable, its maker and model. Corbett phones back with a time and the checks planned.
Corbett's Chimney Damper Repair Scope
A prefab fireplace damper is a thin steel blade on a pivot, worked by a handle or chain. Rust, heat warp and a bent rod are the usual faults. Corbett orders the blade or handle listed for that model. On brick chimneys with a rusted throat damper, a top-sealing damper at the flue exit is another route. The written figure names the part and the labor.
Prefab Dampers Are Part of the Listed Unit
Look up inside most Westminster prefab fireplaces and you will find a thin steel flap hinged across the top of the box, moved by a lever or a chain, and tested with the rest of the unit. It fails in a few ways. The blade warps from heat and no longer sits flat, so it leaks cold air in winter and lets warm air up the pipe. Rain coming down the chimney rusts the pivot until it seizes. The linkage between the handle and the blade bends or comes apart, so the handle moves and the blade does not. Because the damper belongs to the listing, the fix is the maker's own damper assembly or blade, ordered by the model on the data plate. Where that part is no longer available, we look for a listed alternative and tell you plainly if none exists.
Some prefab makers have tested and listed a sealing damper that mounts at the top of their pipe, under the cap, with a cable down to the firebox. On those models, fitting one can replace a failed lower damper and close the chimney off more tightly when it is not in use. On models without such a listing, an aftermarket top damper is not an option on a prefab chimney, whatever an advertisement says. Gas log sets bring one more rule: wherever a vented set burns, the damper has to be fixed so it cannot close fully, and a set that has lost that clamp is a hazard we correct on the spot only with your agreement. We check for it on every prefab with a gas line, including ones where you called us about something else.
Brick Fireplace Dampers and the Repair Price
Masonry fireplaces in older Westminster homes usually have a cast iron damper set into the throat above the firebox. These rust where water comes down the flue, crack at the frame after years of heat, and lose their handle or the pin it pivots on. A seized damper can sometimes be freed and cleaned. Once the frame cracks or the blade rusts through, there are two routes. One is a new cast unit in the throat, which may mean chiseling out some masonry to fit it. The other keeps the old blade wired open and moves the sealing job up to the flue's top end. A top damper on a brick chimney also covers the flue when shut, doing a cap's job between fires, and it seals better than a cast iron blade. Which route suits depends on the flue size, the condition of the old frame and whether you burn wood or gas.
Damper work has no posted price on this site, because a freed pivot, a replacement listed blade and a new top-mounted unit are very different jobs. Once we have looked at the damper and identified the fireplace, you receive a written figure for the option we recommend and any alternatives, with the parts and labor shown. If a top damper replaces the need for a cap on a brick flue, that is reflected in the price rather than charging for both. A camera look up the flue is sometimes needed to judge the frame, and if so it is part of the quote. On the contact page, note whether the damper will not open, will not close or both, and whether the fireplace burns wood or gas. Cypress, Garden Grove and Costa Mesa homes are covered the same way.
Ground Rules on Every Corbett Job
Label Before Parts
Maker and model read before anything is ordered
Listed Replacements
Pieces made for that unit, not generic stand-ins
Figures in Writing
Unlisted work gets a written figure first
Photo Report
Each finding shown, marked fine, watch or fix
Chimney Damper Repair: city pages
Corbett keeps separate pages for its focus cities, with notes on the local tracts, the coastal air and the route neighbors.
Nothing found for that name. The full list on the areas page shows every Corbett city.
More From Corbett
Chimney Sweep
Brushing for metal pipe flues and clay-lined stacks, with brush heads matched to round prefab sections so the joints stay intact.
Read moreChimney Inspection
Level 1 and Level 2 visits that read the model plate first, then check the chimney against what the maker allows.
Read moreChimney Repair
Repairs to metal chimney runs and brick stacks, using listed replacement sections where the original maker's system calls for them.
Read moreFireplace Inspection
A close read of a metal firebox: refractory panels, screen, doors, outer air openings and the label that sets the rules.
Read moreFireplace Repair
Panels, grates, doors, screens and damper parts on prefab fireboxes, replaced with pieces the maker lists for that model.
Read moreChimney Level 2 Inspection
Video of each pipe or flue section on record, with the attic run and the inside of the chase checked too.
Read moreChimney Cap Installation
Termination caps for metal chimneys ordered by pipe brand and diameter, and fitted caps for clay flues on brick stacks.
Read moreChimney Flashing Repair
New step and counter flashing where a brick stack or framed chase meets shingles, tile or a flat roof.
Read moreChimney Masonry Repair
Joint, brick and veneer repair on brick stacks and on the stone or brick facing around prefab fireplaces.
Read moreChimney Rebuilds
Partial or full rebuilds of brick stacks, and full chase rebuilds when a framed chimney's box has rotted.
Read moreFireplace Cleaning
Ash, soot and loose debris lifted from metal fireboxes without scraping the refractory panels or the black enamel.
Read moreGas Fireplace Cleaning
A yearly service for sealed gas units and log sets: burner ports, pilot hood, glass and the vent termination.
Read moreGas Fireplace Repair
Valves, pilots, igniters, thermocouples and remotes on built-in gas units, diagnosed with a meter before any part is ordered.
Read moreFireplace Remodel
Prefab fireboxes refaced, with mantels and hearths sized to the clearances printed on the unit label.
Read moreFireplace Inserts
Gas and wood inserts for prefab and masonry fireplaces, with the insert approved for that firebox before anything is bought.
Read morePellet Stove Repair
Diagnosis of feed motors, igniters, blowers and boards on pellet stoves, with the venting checked along the way.
Read moreWood Stove Repair
Door rope, glass, firebricks, baffles and stovepipe on freestanding wood stoves, set back to the maker's spec.
Read moreGas Logs
Log sets chosen for what a prefab or brick firebox is allowed to burn, then fitted with the right burner and controls.
Read moreChimney Seismic Retrofit
Bracing, strapping or a lightweight rebuild above the roof for brick stacks on otherwise wood-framed homes.
Read moreChimney Crown Repair
Repair or recasting of the cement top on brick chimneys, and replacement of rusted metal tops on framed chases.
Read moreDryer Vent Cleaning
Lint cleared from dryer ducts in tract-house walls, attics and roof runs, then the exterior flap checked for airflow.
Read moreChimney Liner Installation
Stainless liners for inserts, gas conversions and cracked clay flues, with sizes taken from the appliance listing.
Read moreChimney Leak Repair
Water tracked to its entry point on a chimney or chase, then fixed at the source rather than sealed over.
Read moreChimney Waterproofing
Vapor-open repellent for brick stacks, used as the last step once every crack and gap has been closed.
Read moreChimney Chase Cover
Stainless or galvanized tops for framed chimney boxes, made to the measured size of the chase with a crossbreak to shed water.
Read more