Rebuilt From the First Sound Course Up

Request Chimney Rebuilds

Corbett's Chimney Rebuilds Scope

A brick stack that leans or has lost its upper courses gets rebuilt from the point where the masonry is firm. A framed chase with rotted studs or sheathing gets opened, reframed and reclad around the existing listed pipe, or around a new one if the pipe is also spent. Corbett writes the scope with drawings of what comes off and what goes back.

Brick stacks rebuilt from firm courses up
Rotted chase framing opened and replaced
Siding or stucco matched on the new box
Listed pipe reused or replaced
Scope drawn up before demolition

Brick That Can No Longer Hold Itself Together

Repointing works on brick whose courses still grip one another. Once the upper part of a stack has lost that bond, with bricks that rock under a hand, cracks that run through the units rather than around them, or a lean you can see from the street, new mortar on the surface does nothing for the structure underneath. In Westminster, the brick chimneys that reach this point are mostly on the older streets, and many have been shaken by past Southern California quakes as well as worn by decades of weather. The repair is to dismantle the loose section down to courses that are still firm, check the flue tile and any steel inside, and lay the stack back up with new mortar, a fresh crown, new flashing and a cap. Old brick is reused where it cleans up sound and is mixed with matched brick where it does not.

Some owners use a rebuild to change the chimney rather than copy it. A stack that served a fireplace no one uses can be taken down below the roof and the roof closed over it. A tall, heavy stack can come back shorter, within what the fire code allows for clearance above the roof. And a brick stack can sometimes be replaced above the roofline by a framed chase around a listed metal chimney, which is far lighter, though that only works when the appliance below is paired with a matching listed pipe. Each of these gets weighed with you on the roof, not chosen for you. The written quote describes how far down the work goes, what goes back, and what happens if the brick below turns out softer than it looked, so a change in scope is never a surprise on the final bill.

Rebuilding a Prefab Chase Around Its Pipe

The prefab version of a rebuild happens out of sight for years. A rusted chase top drips into the box, water runs down the inside of the framing, and the studs, sheathing and plate at the base slowly rot while the stucco or siding on the outside still looks fine. By the time a soft spot shows or the chase starts to lean away from the house, the framing inside may be beyond patching. A chase rebuild opens the box, takes out the rotted lumber and sheathing, and replaces it to the original size and shape, with house wrap and flashing set properly where the chase meets the roof and the wall. The cladding goes back in matching stucco or siding. Before closing it up we check the metal chimney inside: its supports, its firestops, its clearance to the new framing, and its joints.

If the pipe is sound, it stays, and so does the fireplace below it. If the water has rusted the pipe or the box at its base, those parts are replaced from the fireplace's listing in the same job, since the chase is open and this is the cheapest moment to do it. A new chase top in stainless or aluminum goes on last, sized to the rebuilt framing, with the storm collar and cap the manual calls for. Chase rebuilds in Westminster, Westminster's neighbors in Garden Grove and Cypress, and the coast side in Costa Mesa are scoped after we open a small test area or look in from the attic, because the extent of rot cannot be judged from outside. You receive a written scope that names the framing to be replaced, the cladding, and any listed parts that go in with it.

Ground Rules on Every Corbett Job

Label Before Parts

Maker and model read before anything is ordered

Listed Replacements

Pieces made for that unit, not generic stand-ins

Figures in Writing

Unlisted work gets a written figure first

Photo Report

Each finding shown, marked fine, watch or fix

More From Corbett

Chimney Sweep

Brushing for metal pipe flues and clay-lined stacks, with brush heads matched to round prefab sections so the joints stay intact.

Read more

Chimney Inspection

Level 1 and Level 2 visits that read the model plate first, then check the chimney against what the maker allows.

Read more

Chimney Repair

Repairs to metal chimney runs and brick stacks, using listed replacement sections where the original maker's system calls for them.

Read more

Fireplace Inspection

A close read of a metal firebox: refractory panels, screen, doors, outer air openings and the label that sets the rules.

Read more

Fireplace Repair

Panels, grates, doors, screens and damper parts on prefab fireboxes, replaced with pieces the maker lists for that model.

Read more

Chimney Level 2 Inspection

Video of each pipe or flue section on record, with the attic run and the inside of the chase checked too.

Read more

Chimney Cap Installation

Termination caps for metal chimneys ordered by pipe brand and diameter, and fitted caps for clay flues on brick stacks.

Read more

Chimney Flashing Repair

New step and counter flashing where a brick stack or framed chase meets shingles, tile or a flat roof.

Read more

Chimney Masonry Repair

Joint, brick and veneer repair on brick stacks and on the stone or brick facing around prefab fireplaces.

Read more

Fireplace Cleaning

Ash, soot and loose debris lifted from metal fireboxes without scraping the refractory panels or the black enamel.

Read more

Gas Fireplace Cleaning

A yearly service for sealed gas units and log sets: burner ports, pilot hood, glass and the vent termination.

Read more

Gas Fireplace Repair

Valves, pilots, igniters, thermocouples and remotes on built-in gas units, diagnosed with a meter before any part is ordered.

Read more

Fireplace Remodel

Prefab fireboxes refaced, with mantels and hearths sized to the clearances printed on the unit label.

Read more

Fireplace Inserts

Gas and wood inserts for prefab and masonry fireplaces, with the insert approved for that firebox before anything is bought.

Read more

Pellet Stove Repair

Diagnosis of feed motors, igniters, blowers and boards on pellet stoves, with the venting checked along the way.

Read more

Wood Stove Repair

Door rope, glass, firebricks, baffles and stovepipe on freestanding wood stoves, set back to the maker's spec.

Read more

Gas Logs

Log sets chosen for what a prefab or brick firebox is allowed to burn, then fitted with the right burner and controls.

Read more

Chimney Seismic Retrofit

Bracing, strapping or a lightweight rebuild above the roof for brick stacks on otherwise wood-framed homes.

Read more

Chimney Crown Repair

Repair or recasting of the cement top on brick chimneys, and replacement of rusted metal tops on framed chases.

Read more

Dryer Vent Cleaning

Lint cleared from dryer ducts in tract-house walls, attics and roof runs, then the exterior flap checked for airflow.

Read more

Chimney Liner Installation

Stainless liners for inserts, gas conversions and cracked clay flues, with sizes taken from the appliance listing.

Read more

Chimney Leak Repair

Water tracked to its entry point on a chimney or chase, then fixed at the source rather than sealed over.

Read more

Chimney Waterproofing

Vapor-open repellent for brick stacks, used as the last step once every crack and gap has been closed.

Read more

Chimney Damper Repair

Damper blades, handles, chains and springs on prefab fireplaces, plus top-sealing dampers for brick flues.

Read more

Chimney Chase Cover

Stainless or galvanized tops for framed chimney boxes, made to the measured size of the chase with a crossbreak to shed water.

Read more
Call (657) 222-6961